{"id":45905,"date":"2022-06-13T16:06:16","date_gmt":"2022-06-13T14:06:16","guid":{"rendered":"https:\/\/www.zhermack.com\/come-prendere-impronta-dentale\/"},"modified":"2023-10-13T15:51:17","modified_gmt":"2023-10-13T13:51:17","slug":"como-tomar-una-impresion-dental","status":"publish","type":"page","link":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/","title":{"rendered":"C\u00f3mo tomar una impresi\u00f3n dental &#8211; FAQs"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column width=\u00bb1\/6&#8243;][\/vc_column][vc_column width=\u00bb2\/3&#8243;][vc_empty_space][vc_column_text]\u00cdndice:<\/p>\n<ul>\n<li style=\"text-align: left;\"><em><a href=\"#1\">Alginatos<\/a><\/em><\/li>\n<li style=\"text-align: left;\"><em><a href=\"#2\">Siliconas de adici\u00f3n<\/a><\/em><\/li>\n<li style=\"text-align: left;\"><em><span style=\"font-weight: 400;\"><a href=\"#3\">Registro de mordida<\/a><br \/>\n<\/span><\/em><\/li>\n<li style=\"text-align: left;\"><em><span style=\"font-weight: 400;\"><a href=\"#4\">Siliconas de condensaci\u00f3n<\/a><br \/>\n<\/span><\/em><\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][vc_column width=\u00bb1\/6&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=\u00bb1\/6&#8243;][\/vc_column][vc_column width=\u00bb2\/3&#8243;][vc_empty_space][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h2 id=\"1\">Alginatos<\/h2>\n<p>[\/vc_column_text][vc_separator color=\u00bbblack\u00bb][vc_empty_space][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Medici\u00f3n<\/span><\/h3>\n<h4>\u00bfPor qu\u00e9 es importante medir correctamente la proporci\u00f3n indicada de agua y polvo tal y como est\u00e1 indicado en las instrucciones?<\/h4>\n<p>Aunque el uso del alginato es sencillo, la correcta dosificaci\u00f3n agua\/polvo influye en las propiedades del material [1].<\/p>\n<p>Una proporci\u00f3n incorrecta agua\/polvo afectar\u00eda a la consistencia del material. Una dosificaci\u00f3n incorrecta agua\/polvo puede tambi\u00e9n afectar a las prestaciones declaradas del producto en lo relativo a sus caracter\u00edsticas mec\u00e1nicas, sus tiempos y su estabilidad dimensional.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42497 lazyload\" data-src=\"\/public\/uploads\/\/alginati-dosaggio-300x201.jpg\" alt=\"alginati_dosaggio\" width=\"300\" height=\"201\" data-srcset=\"\/public\/uploads\/alginati-dosaggio-300x201.jpg 300w, \/public\/uploads\/alginati-dosaggio-768x514.jpg 768w, \/public\/uploads\/alginati-dosaggio-50x33.jpg 50w, \/public\/uploads\/alginati-dosaggio.jpg 968w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/201;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Mezcla<\/span><\/h3>\n<h4>\u00bfPor qu\u00e9 se debe a\u00f1adir el agua al polvo y no al rev\u00e9s?<\/h4>\n<p>Cuando se realiza una mezcla manual, es preferible a\u00f1adir el agua al polvo y no al rev\u00e9s para evitar reducir la porosidad en superficie de la mezcla [2].<\/p>\n<blockquote><p>\u00bfQuieres saber m\u00e1s? Descubre <a href=\"https:\/\/magazine.zhermack.com\/es\/estudio-es\/mezclado-de-alginatos-instrucciones-para-conseguir-un-resultado-optimo\/\" target=\"_blank\" rel=\"noopener\">c\u00f3mo conseguir un resultado \u00f3ptimo en la mezcla de alginatos<\/a>.<\/p><\/blockquote>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42505 lazyload\" data-src=\"\/public\/uploads\/\/alginati-miscelazione-300x201.jpg\" alt=\"alginati-miscelazione\" width=\"300\" height=\"201\" data-srcset=\"\/public\/uploads\/alginati-miscelazione-300x201.jpg 300w, \/public\/uploads\/alginati-miscelazione-768x514.jpg 768w, \/public\/uploads\/alginati-miscelazione-50x33.jpg 50w, \/public\/uploads\/alginati-miscelazione.jpg 968w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/201;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Toma de impresi\u00f3n<\/span><\/h3>\n<h4>\u00bfQu\u00e9 tipo de cubeta es mejor utilizar?<\/h4>\n<p>El tipo de cubeta depende del caso cl\u00ednico y de las preferencias y de los h\u00e1bitos del profesional. Para mejorar la retenci\u00f3n entre el alginato y la cubeta, es recomendable o bien utilizar una cubeta perforada o bien utilizar un adhesivo espec\u00edfico para alginatos [3].<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42573 lazyload\" data-src=\"\/public\/uploads\/\/zhermack_15-retusche_1-1-300x200.jpg\" alt=\"\" width=\"300\" height=\"200\" data-srcset=\"\/public\/uploads\/zhermack_15-retusche_1-1-300x200.jpg 300w, \/public\/uploads\/zhermack_15-retusche_1-1-1024x683.jpg 1024w, \/public\/uploads\/zhermack_15-retusche_1-1-768x512.jpg 768w, \/public\/uploads\/zhermack_15-retusche_1-1-50x33.jpg 50w, \/public\/uploads\/zhermack_15-retusche_1-1.jpg 1500w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/200;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Desinfecci\u00f3n y conservaci\u00f3n<\/span><\/h3>\n<h4>\u00bfPodr\u00eda da\u00f1arse la impresi\u00f3n si la dejo sumergida en la soluci\u00f3n desinfectante?<\/h4>\n<p>Dejar la impresi\u00f3n en la soluci\u00f3n desinfectante m\u00e1s tiempo de lo indicado por el fabricante puede da\u00f1ar la impresi\u00f3n y causar cambios dimensionales. los hidrocoloides son por naturaleza hidr\u00f3filos, y por lo tanto tienden a hincharse cuando est\u00e1n sumergidos en agua o en un desinfectante [4].<\/p>\n<h4>\u00bfC\u00f3mo deber\u00eda conservarse una impresi\u00f3n?<\/h4>\n<p>Si no se puede vaciar inmediatamente la impresi\u00f3n, eliminar el exceso de agua y conservar la impresi\u00f3n en una bolsa herm\u00e9tica de polietileno a temperatura ambiente (23\u00b0C).<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42489 lazyload\" data-src=\"\/public\/uploads\/\/alginati-disnfezione-conservazione-300x200.jpg\" alt=\"alginati_disinfezione_conservazione\" width=\"300\" height=\"200\" data-srcset=\"\/public\/uploads\/alginati-disnfezione-conservazione-300x200.jpg 300w, \/public\/uploads\/alginati-disnfezione-conservazione-1024x683.jpg 1024w, \/public\/uploads\/alginati-disnfezione-conservazione-768x512.jpg 768w, \/public\/uploads\/alginati-disnfezione-conservazione-1536x1025.jpg 1536w, \/public\/uploads\/alginati-disnfezione-conservazione-50x33.jpg 50w, \/public\/uploads\/alginati-disnfezione-conservazione.jpg 1988w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/200;\" \/>[\/vc_column_text][\/vc_column][vc_column width=\u00bb1\/6&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=\u00bb1\/6&#8243;][\/vc_column][vc_column width=\u00bb2\/3&#8243;][vc_empty_space][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h2 id=\"2\">Siliconas de adici\u00f3n: Elite HD+ e Hydrorise System<\/h2>\n<p>[\/vc_column_text][vc_separator color=\u00bbblack\u00bb][vc_empty_space][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Dosificaci\u00f3n de los productos<\/span><\/h3>\n<h4>\u00bfPor qu\u00e9 es importante NO intercambiar los medidores de la base y del catalizador?<\/h4>\n<p>El intercambio de los medidores cuando se est\u00e1n dosificando los productos (dosificar la base con el medidor del catalizador y viceversa) provoca la contaminaci\u00f3n de la base y\/o catalizador, lo que impide su correcta polimerizaci\u00f3n.<\/p>\n<h4>\u00bfSe puede recolocar el tap\u00f3n en el cartucho (50 ml y 380 ml) despu\u00e9s de su uso?<\/h4>\n<p>No, una vez retirado del cartucho se debe tirar a la basura para evitar el riesgo de contaminaci\u00f3n entre la base y el catalizador.<br \/>\nDespu\u00e9s de su uso, es recomendable conservar la punta mezcladora en el cartucho hasta su siguiente uso.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42545 lazyload\" data-src=\"\/public\/uploads\/\/ZH-Application-Image-Villarroel-Milko-Elite-HD-Manipulation-1-300x200.jpg\" alt=\"ZH-Application-Image-Villarroel-Milko-Elite-HD+-Manipulation-1\" width=\"300\" height=\"200\" data-srcset=\"\/public\/uploads\/ZH-Application-Image-Villarroel-Milko-Elite-HD-Manipulation-1-300x200.jpg 300w, \/public\/uploads\/ZH-Application-Image-Villarroel-Milko-Elite-HD-Manipulation-1-1024x683.jpg 1024w, \/public\/uploads\/ZH-Application-Image-Villarroel-Milko-Elite-HD-Manipulation-1-768x512.jpg 768w, \/public\/uploads\/ZH-Application-Image-Villarroel-Milko-Elite-HD-Manipulation-1-50x33.jpg 50w, \/public\/uploads\/ZH-Application-Image-Villarroel-Milko-Elite-HD-Manipulation-1.jpg 1296w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/200;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Sangrado del material<\/span><\/h3>\n<h4>Antes de usar los cartuchos de 50 ml y de 380 ml, \u00bfpor qu\u00e9 es siempre importante (antes de cada uso) sangrar el material antes de insertar la punta mezcladora?<\/h4>\n<p>Es importante sangrar el material antes de cada uso para asegurarnos de que la cantidad de base y de catalizador sea la misma. Si no fuera el caso, la mezcla de los dos componentes no ser\u00eda \u00f3ptima, con consecuencias negativas en la polimerizaci\u00f3n del material.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42529 lazyload\" data-src=\"\/public\/uploads\/\/estrusione-pitto-300x180.jpg\" alt=\"estrusione-pitto\" width=\"300\" height=\"180\" data-srcset=\"\/public\/uploads\/estrusione-pitto-300x180.jpg 300w, \/public\/uploads\/estrusione-pitto-50x30.jpg 50w, \/public\/uploads\/estrusione-pitto.jpg 768w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/180;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Guantes<\/span><\/h3>\n<h4>\u00bfSe puede manipular el material con guantes de l\u00e1tex?<\/h4>\n<p>No, las siliconas de adici\u00f3n no pueden ser manipuladas utilizando guantes de l\u00e1tex porque interfiere con el catalizador de platino e impide su polimerizaci\u00f3n.<\/p>\n<p>En su lugar, se pueden utilizar guantes de vinilo o de nitrilo.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42553 lazyload\" data-src=\"\/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-300x200.jpg\" alt=\"ZH-ellite-hd-zetaplus-guanti\" width=\"300\" height=\"200\" data-srcset=\"\/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-300x200.jpg 300w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-1024x681.jpg 1024w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-768x511.jpg 768w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-1536x1022.jpg 1536w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-2048x1363.jpg 2048w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-50x33.jpg 50w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/200;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Desinfecci\u00f3n<\/span><\/h3>\n<h4>Si desinfecto la impresi\u00f3n (incluido por inmersi\u00f3n) \u00bftendr\u00e1 consecuencias para su exactitud?<\/h4>\n<p>No, si los desinfectantes que contienen sales de amonio cuaternario o alcohol se utilizan siguiendo las instrucciones (tiempo de contacto y porcentaje de diluci\u00f3n), el material no se ver\u00e1 sometido a cambios significativos en t\u00e9rminos de estabilidad dimensional o de reproducci\u00f3n de detalles en superficie.<\/p>\n<p>Se deben siempre desinfectar las impresiones antes de enviarlas al laboratorio para (reducir el riesgo de contaminaci\u00f3n cruzada.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42489 lazyload\" data-src=\"\/public\/uploads\/\/alginati-disnfezione-conservazione-300x200.jpg\" alt=\"alginati_disinfezione_conservazione\" width=\"300\" height=\"200\" data-srcset=\"\/public\/uploads\/alginati-disnfezione-conservazione-300x200.jpg 300w, \/public\/uploads\/alginati-disnfezione-conservazione-1024x683.jpg 1024w, \/public\/uploads\/alginati-disnfezione-conservazione-768x512.jpg 768w, \/public\/uploads\/alginati-disnfezione-conservazione-1536x1025.jpg 1536w, \/public\/uploads\/alginati-disnfezione-conservazione-50x33.jpg 50w, \/public\/uploads\/alginati-disnfezione-conservazione.jpg 1988w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/200;\" \/>[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=\u00bb1\/6&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=\u00bb1\/6&#8243;][\/vc_column][vc_column width=\u00bb2\/3&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h2 id=\"3\">Registro de mordida<\/h2>\n<p>[\/vc_column_text][vc_separator color=\u00bbblack\u00bb][vc_empty_space][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Posicionamiento<\/span><\/h3>\n<h4>\u00bfEn qu\u00e9 sentido es la tixotrop\u00eda ventajosa en un material para el registro de mordida?<\/h4>\n<p>Un material tixotr\u00f3pico se caracteriza por el hecho de que no fluye cuando se aplica sobre el plano oclusal y no gotea cuando est\u00e1 sometido a una fuerza mec\u00e1nica. Esta caracter\u00edstica permite una aplicaci\u00f3n sencilla del material.<\/p>\n<blockquote><p>\u00bfQuieres saber m\u00e1s? Descubre el <a href=\"https:\/\/magazine.zhermack.com\/es\/estudio-es\/el-registro-oclusal-con-materiales-tixotropicos\/\" target=\"_blank\" rel=\"noopener\">registro oclusal con materiales tixotr\u00f3picos<\/a>.<\/p><\/blockquote>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42473 lazyload\" data-src=\"\/public\/uploads\/\/1-1-300x199.jpg\" alt=\"bite_registration_posizionamento\" width=\"300\" height=\"199\" data-srcset=\"\/public\/uploads\/1-1-300x199.jpg 300w, \/public\/uploads\/1-1-1024x678.jpg 1024w, \/public\/uploads\/1-1-768x509.jpg 768w, \/public\/uploads\/1-1-50x33.jpg 50w, \/public\/uploads\/1-1.jpg 1232w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/199;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Oclusi\u00f3n<\/span><\/h3>\n<h4>\u00bfPor qu\u00e9 es importante que el material tenga una consistencia imperceptible?<\/h4>\n<p>La consistencia imperceptible del material significa que no interfiere con la oclusi\u00f3n, lo que evita los desplazamientos de los dientes o de los maxilares, lo cual provoca errores. [1]<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42481 lazyload\" data-src=\"\/public\/uploads\/\/3-1-300x199.jpg\" alt=\"bite_registration_occlusione\" width=\"300\" height=\"199\" data-srcset=\"\/public\/uploads\/3-1-300x199.jpg 300w, \/public\/uploads\/3-1-1024x678.jpg 1024w, \/public\/uploads\/3-1-768x509.jpg 768w, \/public\/uploads\/3-1-50x33.jpg 50w, \/public\/uploads\/3-1.jpg 1232w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/199;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Remoci\u00f3n<\/span><\/h3>\n<h4>\u00bfPor qu\u00e9 el material no est\u00e1 polimerizado cuando lo retiramos de la boca del paciente?<\/h4>\n<p>Se puede inhibir la polimerizaci\u00f3n de las siliconas por adici\u00f3n en caso de contaminaci\u00f3n por el l\u00e1tex, por soluciones para la retracci\u00f3n gingival, por el poli\u00e9ter o residuos de resina acr\u00edlica o bis-acr\u00edlica.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42537 lazyload\" data-src=\"\/public\/uploads\/\/ZH-Application-Image-Barbaglia-Alessandro-Occlufast-1-300x199.jpg\" alt=\"ZH_Application_Image_Barbaglia_Alessandro_Occlufast\" width=\"300\" height=\"199\" data-srcset=\"\/public\/uploads\/ZH-Application-Image-Barbaglia-Alessandro-Occlufast-1-300x199.jpg 300w, \/public\/uploads\/ZH-Application-Image-Barbaglia-Alessandro-Occlufast-1-1024x678.jpg 1024w, \/public\/uploads\/ZH-Application-Image-Barbaglia-Alessandro-Occlufast-1-768x509.jpg 768w, \/public\/uploads\/ZH-Application-Image-Barbaglia-Alessandro-Occlufast-1-50x33.jpg 50w, \/public\/uploads\/ZH-Application-Image-Barbaglia-Alessandro-Occlufast-1.jpg 1232w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/199;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Desinfecci\u00f3n<\/span><\/h3>\n<h4>\u00bfPor qu\u00e9 es importante para un material permanecer estable incluso tras la desinfecci\u00f3n?<\/h4>\n<p>Cualquier cambio dimensional en el registro de mordida afecta a la exactitud de la relaci\u00f3n oclusal. Podr\u00eda provocar que el prot\u00e9sico dental monte los modelos de yeso en el articulador en una posici\u00f3n diferente de la posici\u00f3n medida en la boca del paciente.<\/p>\n<p>Esto requerir\u00e1 por consiguiente ajustar la pr\u00f3tesis hecha en el modelo una vez colocada en boca. [2]<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42489 lazyload\" data-src=\"\/public\/uploads\/\/alginati-disnfezione-conservazione-300x200.jpg\" alt=\"alginati_disinfezione_conservazione\" width=\"300\" height=\"200\" data-srcset=\"\/public\/uploads\/alginati-disnfezione-conservazione-300x200.jpg 300w, \/public\/uploads\/alginati-disnfezione-conservazione-1024x683.jpg 1024w, \/public\/uploads\/alginati-disnfezione-conservazione-768x512.jpg 768w, \/public\/uploads\/alginati-disnfezione-conservazione-1536x1025.jpg 1536w, \/public\/uploads\/alginati-disnfezione-conservazione-50x33.jpg 50w, \/public\/uploads\/alginati-disnfezione-conservazione.jpg 1988w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/200;\" \/>[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=\u00bb1\/6&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=\u00bb1\/6&#8243;][\/vc_column][vc_column width=\u00bb2\/3&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h2 id=\"4\">Siliconas de condensaci\u00f3n: Zetaplus<\/h2>\n<p>[\/vc_column_text][vc_separator color=\u00bbblack\u00bb][vc_empty_space][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Dosificaci\u00f3n del producto<\/span><\/h3>\n<h4>\u00bfPor qu\u00e9 es importante respetar la proporci\u00f3n base\/catalizador al dosificar los productos?<\/h4>\n<p>Una dosificaci\u00f3n incorrecta del catalizador provoca variaciones en las propiedades qu\u00edmicas y f\u00edsicas del material y adem\u00e1s influye en las prestaciones del producto.<\/p>\n<p>Por ejemplo, utilizar m\u00e1s catalizador del indicado en las Instrucciones de uso provoca que la impresi\u00f3n tenga una peor estabilidad dimensional y acorta tanto el tiempo de trabajo como el tiempo en boca.<\/p>\n<blockquote><p>\u00bfQuieres saber m\u00e1s? Descubre <a href=\"https:\/\/www.zhermack.com\/es\/product\/zetaplus-es\/\" target=\"_blank\" rel=\"noopener\">las caracter\u00edsticas y ventajas de Zetaplus<\/a>.<\/p><\/blockquote>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42561 lazyload\" data-src=\"\/public\/uploads\/\/Zhermack_11-300x200.jpg\" alt=\"Zhermack_dosaggio_zetaplus\" width=\"300\" height=\"200\" data-srcset=\"\/public\/uploads\/Zhermack_11-300x200.jpg 300w, \/public\/uploads\/Zhermack_11-1024x683.jpg 1024w, \/public\/uploads\/Zhermack_11-768x512.jpg 768w, \/public\/uploads\/Zhermack_11-50x33.jpg 50w, \/public\/uploads\/Zhermack_11.jpg 1096w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/200;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Guantes<\/span><\/h3>\n<h4>\u00bfSe pueden manipular los materiales con guantes de l\u00e1tex?<\/h4>\n<p>S\u00ed, se pueden manipular las siliconas por condensaci\u00f3n con guantes de l\u00e1tex, de vinilo o de nitrilo sin riesgo a que afecten a sus prestaciones.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42553 lazyload\" data-src=\"\/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-300x200.jpg\" alt=\"ZH-ellite-hd-zetaplus-guanti\" width=\"300\" height=\"200\" data-srcset=\"\/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-300x200.jpg 300w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-1024x681.jpg 1024w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-768x511.jpg 768w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-1536x1022.jpg 1536w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-2048x1363.jpg 2048w, \/public\/uploads\/ZH-ellite-hd-zetaplus-guanti-50x33.jpg 50w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/200;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Compatibilidad entre materiales<\/span><\/h3>\n<h4>\u00bfPuedo utilizar una silicona de condensaci\u00f3n como \u201ctray material\u201d y una silicona de adici\u00f3n en la preparaci\u00f3n?<\/h4>\n<p>No, las siliconas de adici\u00f3n y de condensaci\u00f3n no deben usarse juntas. Zhermack no garantiza una correcta adhesi\u00f3n entre los dos materiales ya que qu\u00edmicamente son muy diferentes.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42521 lazyload\" data-src=\"\/public\/uploads\/\/DSCN2368-300x225.jpg\" alt=\"zetaplus_comparazione_materiali\" width=\"300\" height=\"225\" data-srcset=\"\/public\/uploads\/DSCN2368-300x225.jpg 300w, \/public\/uploads\/DSCN2368-1024x768.jpg 1024w, \/public\/uploads\/DSCN2368-768x576.jpg 768w, \/public\/uploads\/DSCN2368-1536x1152.jpg 1536w, \/public\/uploads\/DSCN2368-50x38.jpg 50w, \/public\/uploads\/DSCN2368.jpg 1600w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/225;\" \/>[\/vc_column_text][vc_empty_space][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h3><span style=\"color: #ffcc00;\">Desinfecci\u00f3n<\/span><\/h3>\n<h4>Si desinfecto la impresi\u00f3n (incluido por inmersi\u00f3n), \u00bftendr\u00e1 consecuencias en su exactitud?<\/h4>\n<p>No, si se utilizan desinfectantes que contengan sales de amonio cuaternario o alcoholes siguiendo las instrucciones de uso (tiempo de contacto y diluci\u00f3n), el material no se ver\u00e1 sometido a cambios significativos en lo que se refiere a la estabilidad dimensional o a la reproducci\u00f3n de detalles en superficie.<\/p>\n<p>Se deben siempre desinfectar las impresiones antes de mandarlas al laboratorio, para as\u00ed reducir el riesgo de contaminaci\u00f3n cruzada.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-42489 lazyload\" data-src=\"\/public\/uploads\/\/alginati-disnfezione-conservazione-300x200.jpg\" alt=\"alginati_disinfezione_conservazione\" width=\"300\" height=\"200\" data-srcset=\"\/public\/uploads\/alginati-disnfezione-conservazione-300x200.jpg 300w, \/public\/uploads\/alginati-disnfezione-conservazione-1024x683.jpg 1024w, \/public\/uploads\/alginati-disnfezione-conservazione-768x512.jpg 768w, \/public\/uploads\/alginati-disnfezione-conservazione-1536x1025.jpg 1536w, \/public\/uploads\/alginati-disnfezione-conservazione-50x33.jpg 50w, \/public\/uploads\/alginati-disnfezione-conservazione.jpg 1988w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/200;\" \/>[\/vc_column_text][vc_empty_space][vc_separator color=\u00bbblack\u00bb][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h5>Notas Alginatos<\/h5>\n<p>[1] Dreesen K, Kellens A, Wevers M, Thilakarathne P, Willems G. The influence of mixing methods and disinfectant on the physical properties of alginate impression materials. European journal of orthodontics.2012; 35(3). doi: 10.1093\/ejo\/cjs031<br \/>\n[2] McDaniel TF, Kramer RT, Im F, Snow D. Effects of mixing technique on bubble formation in alginate impression material. General Dentistry, 2013 Sep-Oct; 61(6): 35-39[2]: A. Punj, D. Bompolaki, J. Garaicoa, Dental Impression Materials and Techniques., Dent Clin North Am., 2017<br \/>\n[3] Thirunavakarasu R, Nittla P. P, Alginate impression material-a review, Drug invention today. 2018; 10(4): 3556-3561. ISSN: 0975-7619<br \/>\n[4] Nandini VV, Venkatesh KV, Nair KC. Alginate impressions: A practical perspective. J Conserv Dent. 2008;11(1):37\u201341. doi : 10.4103\/0972-0707.43416[\/vc_column_text][vc_separator][vc_column_text 0=\u00bb\u00bb]<\/p>\n<h5>Notas De Registro Oclusal<\/h5>\n<p>[1] Mobilio M, Catapano S. Effect of experimental jaw muscle pain on occlusal contacts. Journal of Oral Rehabilitation. 2011; 38(6): 404-409. doi: 10.1111\/j.1365-2842.2010.02173.x<br \/>\n[2] Chandu G S, Khan M F, Asnani P. Evaluation and comparison of resistance to compression of various interocclusal recording media: an in vitro study. Journal of international oral health. 2015; 7(5): 24-29. PMID: 26028898[\/vc_column_text][vc_empty_space][vc_empty_space][\/vc_column][vc_column width=\u00bb1\/6&#8243;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=\u00bb1\/6&#8243;][\/vc_column][vc_column width=\u00bb2\/3&#8243;][vc_empty_space][vc_column_text]\u00cdndice: Alginatos Siliconas de adici\u00f3n Registro de mordida Siliconas de condensaci\u00f3n [\/vc_column_text][\/vc_column][vc_column width=\u00bb1\/6&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=\u00bb1\/6&#8243;][\/vc_column][vc_column width=\u00bb2\/3&#8243;][vc_empty_space][vc_column_text 0=\u00bb\u00bb] Alginatos [\/vc_column_text][vc_separator color=\u00bbblack\u00bb][vc_empty_space][vc_column_text 0=\u00bb\u00bb] Medici\u00f3n \u00bfPor qu\u00e9 es importante medir correctamente la proporci\u00f3n indicada de agua y polvo tal y como est\u00e1 indicado en las instrucciones? Aunque el uso del alginato es sencillo, la correcta dosificaci\u00f3n agua\/polvo [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":42638,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-45905","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FAQ - C\u00f3mo tomar una impresi\u00f3n dental | Zhermack<\/title>\n<meta name=\"description\" content=\"Las respuestas a las preguntas m\u00e1s frecuentes sobre la t\u00e9cnica correcta de toma de impresi\u00f3n. Dosificaci\u00f3n, mezcla, compatibilidad y desinfecci\u00f3n de materiales\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ - C\u00f3mo tomar una impresi\u00f3n dental | Zhermack\" \/>\n<meta property=\"og:description\" content=\"Las respuestas a las preguntas m\u00e1s frecuentes sobre la t\u00e9cnica correcta de toma de impresi\u00f3n. Dosificaci\u00f3n, mezcla, compatibilidad y desinfecci\u00f3n de materiales\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/\" \/>\n<meta property=\"og:site_name\" content=\"Zhermack\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-13T13:51:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.zhermack.com\/public\/uploads\/Impronta_H5_1200x800-scaled-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"640\" \/>\n\t<meta property=\"og:image:height\" content=\"427\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.zhermack.com\/public\/uploads\/Impronta_H5_1200x800-scaled-1.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/\",\"url\":\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/\",\"name\":\"FAQ - C\u00f3mo tomar una impresi\u00f3n dental | Zhermack\",\"isPartOf\":{\"@id\":\"https:\/\/www.zhermack.com\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#primaryimage\"},\"thumbnailUrl\":\"\/public\/uploads\/impronta-dentale-particolare.jpg\",\"datePublished\":\"2022-06-13T14:06:16+00:00\",\"dateModified\":\"2023-10-13T13:51:17+00:00\",\"description\":\"Las respuestas a las preguntas m\u00e1s frecuentes sobre la t\u00e9cnica correcta de toma de impresi\u00f3n. Dosificaci\u00f3n, mezcla, compatibilidad y desinfecci\u00f3n de materiales\",\"breadcrumb\":{\"@id\":\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#primaryimage\",\"url\":\"\/public\/uploads\/impronta-dentale-particolare.jpg\",\"contentUrl\":\"\/public\/uploads\/impronta-dentale-particolare.jpg\",\"width\":1199,\"height\":409},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.zhermack.com\/es\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"C\u00f3mo tomar una impresi\u00f3n dental &#8211; FAQs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.zhermack.com\/es\/#website\",\"url\":\"https:\/\/www.zhermack.com\/es\/\",\"name\":\"Zhermack\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.zhermack.com\/es\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.zhermack.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.zhermack.com\/es\/#organization\",\"name\":\"zhermack\",\"url\":\"https:\/\/www.zhermack.com\/es\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.zhermack.com\/es\/#\/schema\/logo\/image\/\",\"url\":\"\/public\/uploads\/logo-1.png\",\"contentUrl\":\"\/public\/uploads\/logo-1.png\",\"width\":284,\"height\":37,\"caption\":\"zhermack\"},\"image\":{\"@id\":\"https:\/\/www.zhermack.com\/es\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FAQ - C\u00f3mo tomar una impresi\u00f3n dental | Zhermack","description":"Las respuestas a las preguntas m\u00e1s frecuentes sobre la t\u00e9cnica correcta de toma de impresi\u00f3n. Dosificaci\u00f3n, mezcla, compatibilidad y desinfecci\u00f3n de materiales","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/","og_locale":"es_ES","og_type":"article","og_title":"FAQ - C\u00f3mo tomar una impresi\u00f3n dental | Zhermack","og_description":"Las respuestas a las preguntas m\u00e1s frecuentes sobre la t\u00e9cnica correcta de toma de impresi\u00f3n. Dosificaci\u00f3n, mezcla, compatibilidad y desinfecci\u00f3n de materiales","og_url":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/","og_site_name":"Zhermack","article_modified_time":"2023-10-13T13:51:17+00:00","og_image":[{"width":640,"height":427,"url":"https:\/\/www.zhermack.com\/public\/uploads\/Impronta_H5_1200x800-scaled-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_image":"https:\/\/www.zhermack.com\/public\/uploads\/Impronta_H5_1200x800-scaled-1.jpg","twitter_misc":{"Tiempo de lectura":"9 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/","url":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/","name":"FAQ - C\u00f3mo tomar una impresi\u00f3n dental | Zhermack","isPartOf":{"@id":"https:\/\/www.zhermack.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#primaryimage"},"image":{"@id":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#primaryimage"},"thumbnailUrl":"\/public\/uploads\/impronta-dentale-particolare.jpg","datePublished":"2022-06-13T14:06:16+00:00","dateModified":"2023-10-13T13:51:17+00:00","description":"Las respuestas a las preguntas m\u00e1s frecuentes sobre la t\u00e9cnica correcta de toma de impresi\u00f3n. Dosificaci\u00f3n, mezcla, compatibilidad y desinfecci\u00f3n de materiales","breadcrumb":{"@id":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#primaryimage","url":"\/public\/uploads\/impronta-dentale-particolare.jpg","contentUrl":"\/public\/uploads\/impronta-dentale-particolare.jpg","width":1199,"height":409},{"@type":"BreadcrumbList","@id":"https:\/\/www.zhermack.com\/es\/como-tomar-una-impresion-dental\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.zhermack.com\/es\/"},{"@type":"ListItem","position":2,"name":"C\u00f3mo tomar una impresi\u00f3n dental &#8211; FAQs"}]},{"@type":"WebSite","@id":"https:\/\/www.zhermack.com\/es\/#website","url":"https:\/\/www.zhermack.com\/es\/","name":"Zhermack","description":"","publisher":{"@id":"https:\/\/www.zhermack.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.zhermack.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.zhermack.com\/es\/#organization","name":"zhermack","url":"https:\/\/www.zhermack.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.zhermack.com\/es\/#\/schema\/logo\/image\/","url":"\/public\/uploads\/logo-1.png","contentUrl":"\/public\/uploads\/logo-1.png","width":284,"height":37,"caption":"zhermack"},"image":{"@id":"https:\/\/www.zhermack.com\/es\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.zhermack.com\/es\/wp-json\/wp\/v2\/pages\/45905","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zhermack.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.zhermack.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.zhermack.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.zhermack.com\/es\/wp-json\/wp\/v2\/comments?post=45905"}],"version-history":[{"count":0,"href":"https:\/\/www.zhermack.com\/es\/wp-json\/wp\/v2\/pages\/45905\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zhermack.com\/es\/wp-json\/wp\/v2\/media\/42638"}],"wp:attachment":[{"href":"https:\/\/www.zhermack.com\/es\/wp-json\/wp\/v2\/media?parent=45905"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}